HEPA filter | frame depth 78 mm
Efficient air filtration in cleanrooms
Applications Features
Article | Article number | Dimensions (W x H x D) [mm] | Filter class acc. to EN 1822 | MPPS efficiency [%] 1 | Filter class acc. to ISO 29463 |
Nominal volume flow [m³/h] |
Initial pressure drop [Pa] | Pleat depth [mm] | |
---|---|---|---|---|---|---|---|---|---|
SF14-M-0305x0610x078x05-N10N | 53447557 | 305 x 610 x 78 | H14 | ≥ 99,995 | ISO 45 H | 300 | 125 | 50 | |
SF14-M-0457x0457x078x05-N10N | 53424912 | 457 x 457 x 78 | H14 | ≥ 99,995 | ISO 45 H | 335 | 125 | 50 | |
SF14-M-0610x0610x078x05-N10N | 53424924 | 610 x 610 x 78 | H14 | ≥ 99,995 | ISO 45 H | 600 | 125 | 50 | |
SF14-M-0610x0762x078x05-N10N | 610 x 762 x 78 | H14 | ≥ 99,995 | ISO 45 H | 750 | 125 | 50 |
Applications
Viledon HEPA filters with MDF frame are used in intake, exhaust and recirculated air filtration in air-conditioning systems with stringent requirements for clean air quality and sterility, e. g.in sophisticated air-conditioning technology (operating theaters, intensive care units in hospitals, laboratories, cleanrooms, etc.)
in sensitive industrial processes
as final filters in ceiling air outlets
Features
High-efficiency micro-glass-fiber papers are used as filter media.
The MiniPleat technology employed ensures flow-friendly geometry and equidistance of the pleats, with homogeneous media velocity coupled with a very low pressure drop. This means particularly cost-efficient and dependable operation plus a quasilaminar outflow.
The frame consists of MDF (medium-density fiber board) and is fully incinerable.
The entire filter element is non-corroding and easy to dispose of, as it is metal-free.
Protection grids on request.
Continuous, homogeneously foamed-on polyurethane gasket; on request also available with a flat gasket.
Each filter element is tested for leakproofing in accordance with EN 1822:2009, and delivered together with the corresponding test certificate.