CCP 810
Reliable Protection Against Corrosion
Viledon ChemControl Pellets are used for the prevention of corrosion. Contaminant gases are removed by means of adsorption, absorption, and chemisorption.
| Article | Diameter [in] |
Face velocity [m/s] |
Bulk density [kg/m³] |
Nominal diameter / Nominal length [mm] |
Removal capacity for H2S of own weight (%) |
Removal capacity for SO2 of own weight (%) |
Removal capacity for Cl2 of own weight [%] |
Box dimensions (L x W x H) [mm] | Crush strength (minimum) [lbs] | Relative humidity [%] | |
|---|---|---|---|---|---|---|---|---|---|---|---|
| CCP810 | .15 | 0,3 - 2,9 | 660 | 3,80; 4 x 8 | 7 | 3 | 4 | 320x320x340 | 4.4 | 10-95 |
Applications
Viledon ChemControl Pellets are used in different areas for the prevention of corrosion caused by acidic gases. Special pellets are utilized for ammonia and chlorine.
Pulp and Paper industry
Petrochemical industry
Mining
Pharmaceutical industry
Data Centers
Labs
Microelectronics
Fertilizer
Features
CCP 810 blended pellets are used in a wide range of applications for the filtration of gaseous contaminants, covering acidic gases and organic substances.
They consist of a 50 : 50 by volume mix of CCP 108 and CCP 610 to provide an excellent combination of their respective properties in terms of adsorption, absorption and chemisorption.
CCP 810 is the first choice when space limitations and onsite conditions require an effective filtration solution regarding the oxidization of contaminants and adsorption of hydrocarbons, aldehydes and VOCs.
Download Material Safety Data Sheets
Hazard and precautionary statements
H314:Causes severe skin burns and eye damage.
H361d:Suspected of damaging the unborn child.
H410:Very toxic to aquatic life with long lasting effects.
P260:Do not breathe dust.
P273:Avoid release to the environment.
P280:Wear protective gloves / eye protection / face protection.
P301+P330+P331:IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P304+P340:IF INHALED: Remove person to fresh air and keep comfortable for breathing.
P305+P351+P338:IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P363:Wash contaminated clothing before reuse.
P391:Collect spillage.
P405:Store locked up.
P501:Dispose of contents/container in accordance with local/regional/national/
international regulations.
Overview of the gas phase filters ChemControl Pellets CCP 810
Gas phase filter ChemControl Pellets CCP 810
Harmful gases are produced in various applications and often bring foul odours with them. They can have a negative effect on the health of employees and damage equipment. Acid gases can also cause costly damage by causing corrosion to electronic equipment. This impairs the efficiency of processes and increases operating costs. With suitable filtration concepts for the removal of harmful gases, you protect people and processes. CCP 810 Gas Phase Filter Pellets can be used to remove acid gases and organic substances in particular.
Areas of application for CCP 810
ChemControl Pellets CCP 810 from Viledon prevent corrosion caused by acid gases in a wide range of applications. Industries such as the pulp and paper, petrochemical, mining and metallurgical, chemical and pharmaceutical industries benefit from the use of ChemControl Pellets CCP 810 for gas phase filtration. They are also used in data centres, laboratories, microelectronics or in the fertiliser industry.
CCP 810 Pellets gas phase filters and their advantages
CCP 810 gas phase filters pellets filter harmful gases for a wide range of applications, especially acid gases and organic substances. As they are made up of half CCP 108 and half CCP 610 pellets, they have an excellent combination of the respective properties in terms of adsorption, absorption and chemisorption.